Conviértete en el experto en control de fluidos de alta presión de primera clase en el mundo.

Suncenter  >  AI - Page Sitemap  >  booster pump system booster development for pressurization
booster pump system booster development for pressurization

booster pump system booster development for pressurization
  • booster pump system booster development for pressurization
  • booster pump system booster development for pressurization
  • booster pump system booster development for pressurization
  • booster pump system booster development for pressurization
  • booster pump system booster development for pressurization
  • booster pump system booster development for pressurization

booster pump system booster development for pressurization

It is the quality booster pump system and excellent service that makes Dongguan Suncenter Fluid Control Equipment Co., Ltd the leader in the industry.
latest_price_title
quantity_needed:
pieces
Correo electrónico:
Company Advantages
1. The design of Suncenter liquid co2 pumps is market-based. It is carefully designed based on dimensions, weight, and characteristics of the product to be packed. The product is widely applied in the gas and petroleum industry
2. The product has many competitive advantages and is widely used in the field. The product is easy to maintain and helps improve productivity
3. Long-term stable performance of the product in the industry has a great advantage. It can be tailored to meet the specific requirements of customers
4. The products are durable and have long service life. The product can be mounted in any position
5. Strict quality control is carried out to ensure product quality and performance in line with industry standards. The product combines principles of simple operation with rugged construction

Air Driven Liquid CO2 Booster Pump-DGG/DGGD Series.


SUNCENTER pumps are air driven at a drive air pressure of 2bar to 8bar by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.


Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal outlet pressure can be calculated.


booster pump system booster development for pressurization-1



DGG Series Liquid CO2 Booster Pumps(Single acting)


booster pump system booster development for pressurization-2
  • DGG Series Liquid CO2 Booster Pumps(Single acting)  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

2-8 bar

6XPL

48

NPT1/2

NPT1/2

29.91

DGG10

10:1

2-8 bar

10XPL

80

NPT1/2

NPT1/2

18.84

DGG16

16:1

2-8 bar

16XPL

128

NPT1/2

NPT1/2

12.42

DGG28

28:1

2-8 bar

28XPL

224

NPT1/2

NPT1/2

7.11

DGG40

40:1

2-8 bar

40XPL

320

NPT1/2

NPT1/2

4.89

DGG64

64:1

2-8 bar

64XPL

512

NPT1/2

NPT3/8

3.08

DGG80

80:1

2-8 bar

80XPL

640

NPT1/2

NPT3/8

2.44

DGG100

100:1

2-8 bar

100XPL

800

NPT1/2

NPT3/8

1.92

DGG130

130:1

2-8 bar

130XPL

1040

NPT1/2

M14X1.5

1.47

DGG175

175:1

2-8 bar

175XPL

1400

NPT3/8

M14X1.5

1.14


DGGD Series Liquid CO2 Pumps(Double acting)


booster pump system booster development for pressurization-3
  • DGGD Series Liquid CO2 Pumps(Double acting) 


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

2-8 bar

4XPL

32

NPT1/2

NPT1/2

70.00

DGGD6

6:1

2-8 bar

6XPL

48

NPT1/2

NPT1/2

48.60

DGGD10

10:1

2-8 bar

10XPL

80

NPT1/2

NPT1/2

30.61

DGGD16

16:1

2-8 bar

16XPL

128

NPT1/2

NPT1/2

19.73

DGGD28

28:1

2-8 bar

28XPL

224

NPT1/2

NPT1/2

11.30

DGGD40

40:1

2-8 bar

40XPL

320

NPT1/2

NPT3/8

7.69

DGGD64

64:1

2-8 bar

64XPL

512

NPT1/2

NPT3/8

4.94

DGGD80

80:1

2-8 bar

80XPL

640

NPT1/2

NPT3/8

3.96

DGGD100

100:1

2-8 bar

100XPL

800

NPT1/2

NPT3/8

3.13

DGGD130

130:1

2-8 bar

130XPL

1040

NPT1/2

M14*1.5

2.40

DGGD175

175:1

2-8 bar

175XPL

1400

NPT3/8

M14*1.5

1.81


booster pump system booster development for pressurization-4
  • Liquid carbon dioxide booster pump and pressurization equipment, commonly used in carbon dioxide supercritical extraction of various plant extracts, material foaming, and carbon dioxide fire extinguisher filling. Among them, carbon dioxide extraction is often used in biopharmaceuticals. Experimental research works by using a special pump for liquid carbon dioxide to pressurize carbon dioxide to a supercritical state, which is used to decompose various elements in plants for easy extraction.


DGGD series liquid CO2 pump working picture


booster pump system booster development for pressurization-5
  • DGGD series liquid CO2 pump working picture



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof 

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable for liquid CO2/liquid+gas mixed CO2/Supercritical CO2

  •   For liquid CO2 cylinder transfer/filling

  •  For CO2 Fire Extinguisher filling 

  •   For Supercritical CO2 extraction


video





Company Features
1. It is the quality booster pump system and excellent service that makes Dongguan Suncenter Fluid Control Equipment Co., Ltd the leader in the industry.
2. Dongguan Suncenter Fluid Control Equipment Co., Ltd has a specialized production base and a sound supply chain for co2 pump .
3. We are committed to honesty and integrity in all our business relationships. The trust of customers is what we pursue. We are willing to maintain a long-term supplying and cooperative relationship for the customers.
There are five basic principles of furniture design being applied to Suncenter liquid co2 pumps. They are respectively "proportion and scale", "focal point and emphasis", "balance", "unity, rhythm, harmony", and "contrast".
The design of Suncenter booster pump system takes many elements into consideration. The style, design, the model, materials are all the prime factors that prompt the designer to take due importance.
Suncenter co2 pump has been rigorously tested in manufacturing. The tests include impact test, fatigue test, static load test, stability test, and so forth.
The design of Suncenter co2 pump is elaborate. It addresses the following areas of research and inquiry: Human Factors (anthropometry and ergonomics), Humanities (psychology, sociology, and human perception), Materials (features and performance), etc.
Seven fundamentals of good furniture design are applied on Suncenter co2 pump. They are Contrast, Proportion, Shape or Form, Line, Texture, Pattern, and Colour.
The product is reliable in high quality and performance.
Mensaje del producto
Chat en línea 编辑模式下无法使用
Deja tu mensaje inputting