Conviértete en el experto en control de fluidos de alta presión de primera clase en el mundo.

Suncenter  >  AI - Page Sitemap  >  nitrogen pumps bench factory price for safety valve calibration
nitrogen pumps bench factory price for safety valve calibration

nitrogen pumps bench factory price for safety valve calibration
  • nitrogen pumps bench factory price for safety valve calibration
  • nitrogen pumps bench factory price for safety valve calibration
  • nitrogen pumps bench factory price for safety valve calibration
  • nitrogen pumps bench factory price for safety valve calibration

nitrogen pumps bench factory price for safety valve calibration

Gas booster pressure test benchSuncenter - Air/Gas pressure test bench are compact and delicacy solution...
latest_price_title
quantity_needed:
pieces
Correo electrónico:
Company Advantages
1. nitrogen pumps is processed by vibration reduction and noise reduction technology. It is stable in operation and low in noise. Moreover, it has a beautiful appearance, smooth lines, and a unique structure.
2. Thanks to advanced production equipment, Dongguan Suncenter Fluid Control Equipment Co., Ltd can make timely delivery. It helps save costs and prevent contamination
3. The part that directly contacts with water will not contaminate the water source. The parts are made of food-grade materials which will not release any toxic substances. The speed of this product can be adjusted steplessly
4. This product is colorfast. It has passed the laboratory testing which creates different conditions such as wet, dry, heat, frost, perspiration, and light. It can be tailored to meet the specific requirements of customers

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


nitrogen pumps bench factory price for safety valve calibration-1



The hottest selling- Model C frame type cabinet picture


nitrogen pumps bench factory price for safety valve calibration-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


nitrogen pumps bench factory price for safety valve calibration-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Company Features
1. In terms of technology competency, Dongguan Suncenter Fluid Control Equipment Co., Ltd is solid and strong.
2. Dongguan Suncenter Fluid Control Equipment Co., Ltd warmly welcomes customers to visit our factory and our sample display room. Call!
Suncenter hydraulic pump test bench is meticulously designed. Principles that include balance, proportion, emphasis, rhythm, and harmony are guidelines that designers follow when designing this product.
Test for Suncenter nitrogen pumps will be practiced for conformance to quality regulations. They include National Basic Safety Technical Specifications for Textiles and Instruction Use for Textiles and Garments.
Suncenter hydraulic pump test bench is required to go through the inspection stage. It will be checked in terms of appearance, faults & stains, and patterns matching.
Suncenter hydraulic pump test bench is stridently inspected in many aspects. It is checked whether there are different shades within the same fabrics, exposed notches, loose or hanging threads, pulled or loose yarns, etc.
The manufacturing process of Suncenter nitrogen pumps involves some aspects. They are market trend research, construction design, fabric selection, sampling, pattern cutting, sewing, and workmanship assessments.
This product is very soft. The chemical softener combines with the fiber to make the product smooth and soft.
Mensaje del producto
Chat en línea 编辑模式下无法使用
Deja tu mensaje inputting