Conviértete en el experto en control de fluidos de alta presión de primera clase en el mundo.

Suncenter  >  AI - Page Sitemap  >  Suncenter bench hydraulic test bench at discount for safety valve calibration
Suncenter bench hydraulic test bench at discount for safety valve calibration

Suncenter bench hydraulic test bench at discount for safety valve calibration

Moq
1 Set
Nombre de la marca
SUNCENTER
Certificado
ISO/CE/SGS
Garantía
13 Months
embalaje
By Plywood case
Puerto de embarque
Shenzhen/Hongkong
Pago
T/T,Western Union,Credit card.
Método de transacción
EXW,FOB,DDP,CIF,CFR
Lugar de origen
Guangdong Province, China (Mainland)
El tiempo de entrega
Within 10-15 working days after received deposit
Precio
latest_price
latest_price_title
quantity_needed:
pieces
Correo electrónico:
Product Details
With the pursuit of excellence, Suncenter Fluid Control Equipment is committed to showing you unique craftsmanship in details.
Company Advantages
1. Suncenter hydraulic test bench has to undergo many quality tests scrutinized by the quality control team. For example, it has passed the high-temperature withstanding test required in the grilling tool industry.
2. Our professional technical team has greatly optimized the performance of our products.
3. The popularity of this product comes from its reliable performance and good durability.
4. To develop sales network, Suncenter has been also focusing on the hydraulic test bench quality assurance.

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter bench hydraulic test bench at discount for safety valve calibration-1



The hottest selling- Model C frame type cabinet picture


Suncenter bench hydraulic test bench at discount for safety valve calibration-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Suncenter bench hydraulic test bench at discount for safety valve calibration-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd, as a professional hydraulic test bench manufacturer, has become a most reliable partner for many companies.
2. All our technician in Dongguan Suncenter Fluid Control Equipment Co., Ltd are well trained to help customers solve problems for gas booster compressor .
3. We conserve water across a wide range of actions, extending from recycling water and installing new technologies to upgrading water treatment plants. We try to achieve our responsible and sustainable practices in our business, from our own quality control to the relationships we have with our suppliers.
Suncenter gas booster compressor is created by the R&D team who spent lots of time and efforts analyzing its thermal performance and the most appropriate contact area for the product and the devices. It is suitable for extreme pressure conditions
Suncenter gas booster compressor is the outcome of thermodynamics knowledge. Its whole body part especially the air circulation parts are made with special materials and circulating layout. This product has a high level of IP
Much advanced quality inspection equipment is used in Suncenter air pressure testing production. It is finely handled by the coordinate measuring machine (CMM), caliper, microcaliper, gauge, and pass meter. It is suitable for extreme pressure conditions
Advanced inspection measures are used in the production of Suncenter gas booster compressor, such as coordinate measuring machine, gauges, roughness tester, and hardness tester. This product is not susceptible to cracks
The law of heat conduction theory has been adopted in the developing of Suncenter air pressure testing. It's specially made to allow the heat to be transferred from the higher temperature region to the lower temperature region. This product is mainly used for the automation process
The product structure is stable. Its mechanical components are designed to be rigid and sturdy to support moving parts. This product has been certified under CE and RoHS
Mensaje del producto
Chat en línea 编辑模式下无法使用
Deja tu mensaje inputting