Conviértete en el experto en control de fluidos de alta presión de primera clase en el mundo.

Suncenter  >  AI - Page Sitemap  >  Suncenter oxygen pressure booster pump type for safety valve calibration
Suncenter oxygen pressure booster pump type for safety valve calibration

Suncenter oxygen pressure booster pump type for safety valve calibration

Moq
1 Set
Nombre de la marca
SUNCENTER
Certificado
ISO/CE/SGS
Garantía
13 Months
embalaje
By Plywood case
Puerto de embarque
Shenzhen/Hongkong
Pago
T/T,Western Union,Credit card.
Método de transacción
EXW,FOB,DDP,CIF,CFR
Lugar de origen
Guangdong Province, China (Mainland)
El tiempo de entrega
Within 10-15 working days after received deposit
Precio
latest_price
latest_price_title
quantity_needed:
pieces
Correo electrónico:

Compressed Air Driven Gas Booster Pump- DGD series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


Suncenter oxygen pressure booster pump type for safety valve calibration-1



DGD series gas booster pumps(Double acting ):


Suncenter oxygen pressure booster pump type for safety valve calibration-2
  • DGD series pumps are double acting, with single air driven heads type.   

  • DGD pumps are available with high quality seals, which provide significantly better service life 

  • Double pump heads with exhaust cooling devices. 

  • All components in contact with the gas are made of stainless steel. 

  • Pipes mounting way are available as customized.


Model

Pressure boost ratio

Min. gas Inlet pressure PA (bar)

Max.gas  Inlet 

pressure PA (bar)

Max. gas outlet pressure PB (bar)

 Driven air pressure PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )



2DGD series gas booster pumps(Double acting, double air driven heads ):


Suncenter oxygen pressure booster pump type for safety valve calibration-3
  • DGD series nitrogen booster pump 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas Inlet 

pressure PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

2DGD10

10:1

3

80

80

2bar-8 bar

10XPL+ PA

1/2 / 1/2

980(at PA of 6 bar )

2DGD25

25:1

6

200

200

2bar-8 bar

25XPL+ PA

3/8 / 3/8

560(at PA of 10 bar )

2DGD40

40:1

25

320

320

2bar-8 bar

40XPL+ PA

3/8 / 3/8

480(at PA of 40 bar )

2DGD60

60:1

30

480

480

2bar-8 bar

60XPL+ PA

3/8 / 3/8

320(at PA of 40 bar )


Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System


Suncenter oxygen pressure booster pump type for safety valve calibration-4


DGS gas booster system = gas booster pump+ following valves, gauges, and parts


Suncenter oxygen pressure booster pump type for safety valve calibration-5


Suncenter - Pneumatic gas booster system are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


The hottest selling- model A and model C cabinet picture


Suncenter oxygen pressure booster pump type for safety valve calibration-6
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Suncenter oxygen pressure booster pump type for safety valve calibration-7
  • DGD series gas booster working picture 


Suncenter oxygen pressure booster pump type for safety valve calibration-8
  • DGS-DGD series gas booster system for nitrogen gas spring charging 

  • Suncenter portable nitrogen spring filling machine is widely used in the production process of high pressure nitrogen gas spring. It is used to inject high nitrogen pressure into the high pressure chamber of nitrogen gas spring. High pressure nitrogen gas spring is often used in relatively accurate automobile molds. The pressure can reach several tons, the volume is small, clean and easy to use. It can also be used for nitrogen spring pressure supplementation. This portable nitrogen spring inflator has the advantages of small size, high pressure and convenient carrying. 



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections 

  •   Pressures to 80Mpa (11,600 psi)

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain 

  •   Best price / performance ratio  

  •   No heat, flame or spark risk and explosion proof   

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





Suncenter pressure booster pump is meticulously manufactured. Its workmanship is done by our professional teams including electronic engineers, programmers, PCB layout editors, and so forth. It produces no strident squeak when used
Suncenter pressure booster pump is made according to strict specifications established by the International Organization for Standardization. From size to the quality of steel used for construction, as well as the allowed gross weight, it complies to every rule. It is not likely to tear paint off the base materials
The quality of Suncenter pressure booster pump is guaranteed. It has passed a comprehensive range of quality control processes such as the detection of hazardous substances in fabrics. This product is widely used in the fields of industrial packaging, offices, advertising, shipping, etc
Suncenter oxygen booster pump must undergo a quality control process. This includes checking the color fastness of the fabric, color correction, and the security of the attachment. It has good temperature resistance performance
Suncenter pressure booster pump has a very practical design. It is carefully designed according to the size, weight, and form of the product to be packaged. The product can provide an excellent sealing function
The feature of pressure booster pump is pressure booster pump, which is worthy of popularization in application. It will not lose its adherence force even stored for a long period
Mensaje del producto
Chat en línea 编辑模式下无法使用
Deja tu mensaje inputting