Conviértete en el experto en control de fluidos de alta presión de primera clase en el mundo.

Suncenter  >  AI - Page Sitemap  >  Suncenter system nitrogen pumps at discount for natural gas boosts pressure
Suncenter system nitrogen pumps at discount for natural gas boosts pressure

Suncenter system nitrogen pumps at discount for natural gas boosts pressure

Moq
1 Set
Nombre de la marca
SUNCENTER
Certificado
ISO/CE/SGS
Garantía
13 Months
embalaje
By Plywood case
Puerto de embarque
Shenzhen/Hongkong
Pago
T/T,Western Union,Credit card.
Método de transacción
EXW,FOB,DDP,CIF,CFR
Lugar de origen
Guangdong Province, China (Mainland)
El tiempo de entrega
Within 10-15 working days after received deposit
Precio
latest_price
latest_price_title
quantity_needed:
pieces
Correo electrónico:
Product Details
With the pursuit of excellence, Suncenter Fluid Control Equipment is committed to showing you unique craftsmanship in details.
Application Scope
The hydro test pump produced by Suncenter Fluid Control Equipment is very popular in the market and is widely used in industry.Suncenter Fluid Control Equipment provides comprehensive and reasonable solutions based on customer's specific situations and needs.
Company Advantages
1. Suncenter has established stable business relationship and service networks in many countries.
2. The product features an easy-to-clean surface. It is either easy to adhere to dust or dirt not retain water stain.
3. People are happy that this product helps them get rid of smelly feet because no proliferation of bacteria and fungi and the bad odor produced.
4. The product looks great and clean. It is especially great for families and groups of friends to create fun and memories. - One of the visitors says.

Gas booster pump system


Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System


Suncenter system nitrogen pumps at discount for natural gas boosts pressure-1


DGS booster system = booster pump+ following valves, gages, and parts


Suncenter system nitrogen pumps at discount for natural gas boosts pressure-2



The hottest selling- model A and model C cabinet picture


Suncenter system nitrogen pumps at discount for natural gas boosts pressure-3
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGS-DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


Technical specification for DGS-DGD Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGS-DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


Technical specification for DGS-2DGD Series:


Model

Pressure boost ratio

Min. gas
   Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGD10

10:1

3

80

80

2bar-8 bar

10XPL+ PA

1/2 / 1/2

980(at PA of 6 bar )

DGS-2DGD25

25:1

6

200

200

2bar-8 bar

25XPL+ PA

3/8 / 3/8

560(at PA of 10 bar )

DGS-2DGD40

40:1

25

320

320

2bar-8 bar

40XPL+ PA

3/8 / 3/8

480(at PA of 40 bar )

DGS-2DGD60

60:1

30

480

480

2bar-8 bar

60XPL+ PA

3/8 / 3/8

320(at PA of 40 bar )


Technical specification for DGS-DGT Series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGS-DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGS-DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


Technical specification for DGS-2DGT series:


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

DGS-2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

DGS-2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

DGS-2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )


Suncenter system nitrogen pumps at discount for natural gas boosts pressure-4



Suncenter system nitrogen pumps at discount for natural gas boosts pressure-5
  • DGS series gas boosters working pictures


Suncenter system nitrogen pumps at discount for natural gas boosts pressure-6


DGS-DGD40 gas booster system for nitrogen gas spring filling

Suncenter system nitrogen pumps at discount for natural gas boosts pressure-7


DGS-DGT series gas boosters for gas cylinder transfer and filling


video





Company Features
1. Engaging in the industry of nitrogen pumps, Dongguan Suncenter Fluid Control Equipment Co., Ltd is a remarkable enterprise.
2. To be one of the most influential enterprise, Suncenter has been doing its utmost to produce hydrostatic pressure test with high quality.
3. Our company is committed to sustainable manufacturing processes. All our manufacturing processes are designed with sustainability and efficiency in mind. Through treating employees fairly and ethically, we fulfill our social responsibility, which is especially true for disabled people or ethnic people. Please contact us! We have a highly motivated goal: to be a major global market player in this industry. Under this, we will invest in pooling talents to strengthen our R&D ability. We strive to achieve the goal through product innovation superiority.
Suncenter air pressure testing is meticulously produced. Its manufacturing processes include areas such as computerized machine control, engineering statistics, ergonomics, and life cycle analysis.
Strictly quality inspection is performed on Suncenter nitrogen pumps. Dimensional tolerances, geometric tolerances, surface roughness, and heat treatment quality will be checked using advanced testing machines.
Basic tests have been performed on Suncenter hydrostatic pressure test. These tests include colorfastness testing, abrasion resistance testing, dimensional stability testing, breathability testing, etc.
Strict production rules and regulations are always the core competitiveness of Suncenter nitrogen pumps. With mature production technology and years of experience in the lighting industry, we are confident to provide customers with quality products.
Conventional and special processing techniques are used in Suncenter hydrostatic pressure test production. They include welding, cutting, and honing.
air pressure testing The surface is specially treated with anti-corrosion technology, which has the characteristics of waterproof and anti-corrosion, not easy to fade and deform, strong and durable, and has a longer service life.
Mensaje del producto
Chat en línea 编辑模式下无法使用
Deja tu mensaje inputting